FX1N-32MR product function description
Product function description
project |
performance |
|
Operation control method |
Stored program repeatedly scanning mode |
|
Input and output control mode |
Batch mode (when executing END instruction), input and output refresh command, pulse capture function |
|
Programming language |
Ladder diagram, SFC stepping instructions |
|
Ladder programming software |
GX Developer, GX Works2 |
|
Program memory |
8K step EEPROM |
|
Type of instruction |
Direct instruction |
27 |
Step ladder instruction |
2 |
|
Basic application instruction |
70 |
|
Instructions speed |
Basic instructions |
0.1μS-0.55μS instruction |
Application instructions |
0.8μS-10μS instruction |
|
input Output |
Input relay X |
X0-X127,128 points |
Output relay Y |
Y0-Y127,128 poinst |
|
Auxiliary relay M |
General use |
M0-M1523,1524 points |
Special use |
M8000-M1535,1152 points( after M500 Power down save) |
|
State S |
S10-S999,1000 points |
|
Timer T |
100MS |
T0-199,200 points |
10MS |
T200-T245,46 points |
|
1MS |
T246-T249,4 points |
|
100MS accumulation |
T250-T255,6 points |
|
Counter C |
Counter 16 bits |
C0-C199,200point(after C100 Power down save) |
Counter 32 bits |
C200-C255,56 points |
|
Data register |
General use |
D0-D500(after D200 Power down save),500point |
Special use |
D8000-D8255,255 points |
|
Indexing |
V7-V0,Z7-Z0,16 points |
|
Nested pointer |
P0-P127,128 points |
|
constant |
K 16 bit |
-32768-32767 |
K 32 bit |
-2 147 483 648-2 147 483 647 |
|
H 16 bit |
0-FFFF |
|
H 32 bit |
0-FFFFFFFF |
27 basic instructions
Mnemonic, name |
function |
Available Soft Components |
[LD] take |
Operation start“a”contact |
XYMSTC |
[LD] take reverse |
Operation start“b”contact |
XYMSTC |
[LDP] take pulse rising edge |
The rising edge detects the start of the operation |
XYMSTC |
[LDF] take the pulse falling edge |
The falling edge detects the start of the operation |
XYMSTC |
[AND] and |
Series“a”contact |
XYMSTC |
[ANI] and reversal |
Series“b”contact |
XYMSTC |
[ANDP] with pulse rising edge |
The rising edge detects“a”series connection |
XYMSTC |
[ANDF] with pulse falling edge |
Falling edge detects serial connection |
XYMSTC |
[OR] or |
Parallel“a”contact |
XYMSTC |
[ORI] or inversion |
Parallel“b”contact |
XYMSTC |
[ORP] or pulse rising edge |
The rising edge detects a parallel connection |
XYMSTC |
[OUT]output |
Coil drive command |
YMSTC |
[SET] set |
Coil hold command |
YMS |
[RST]Reset |
Coil reset command |
YMSTCD |
[PLS] rising edge pulse |
Rising edge detection command |
YM |
[PLF] rising edge pulse |
Falling edge detection instruction |
YM |
[MC] Master |
Connecting coil of common series point |
|
[MCR] master reset |
Clearing coil of common series point |
|
[MPS] onto the stack |
Operational storage |
|
[MRD] read stack |
Storage readout |
|
[MPP] popping |
Save read and reset |
|
[INV]Reverse |
Reverse of operation result |
|
[NOP] empty operation |
No action |
|
[END] end |
End of sequence program |
Two step ladder diagram instructions
STL step ladder |
Step ladder start |
RET return |
Step ladder end |
Application instruction
classification |
FNC NO. |
Instruction mnemonic |
Instruction name |
Procedure flow chart |
00 |
CJ |
Conditional jump |
01 |
CALL |
Subroutine call |
|
02 |
SRET |
Subroutine return |
|
06 |
FEND |
End of main program |
|
07 |
WDT |
Watchdog timer |
|
08 |
FOR |
Repeat range begins |
|
09 |
NEXT |
End of repeat range |
|
Transfer and comparison |
10 |
CMP |
Comparison |
11 |
ZCP |
Regional comparison |
|
12 |
MOV |
Transfer |
|
15 |
BMOV |
Batch transfer |
|
18 |
BCD |
BCD exchange |
|
19 |
BIN |
BIN exchange |
|
Four arithmetic operations |
20 |
ADD |
BIN addition |
21 |
SUB |
BIN subtraction |
|
22 |
MUL |
BIN multiplication |
|
23 |
DIV |
BIN division |
|
24 |
INC |
BIN increment |
|
25 |
DEC |
BIN decrement |
|
26 |
WAND |
Logic and |
|
27 |
WOR |
Logical or |
|
28 |
WXOR |
Logical XOR |
|
Rotation displacement |
34 |
SFTR |
Right shift |
35 |
SFTL |
Left shift |
|
38 |
SFWR |
Shift write |
|
39 |
SFRD |
Shift write out |
|
Bit processing |
40 |
ZRST |
Reset all |
41 |
DECO |
decoding |
|
42 |
ENCO |
coding |
classification |
FNC NO. |
Instruction mnemonic |
Instruction name |
High speed processing |
56 |
SPD |
Pulse density |
57 |
PLSY |
Pulse output |
|
59 |
PLSR |
Adjustable speed pulse output |
|
Easy command |
66 |
ALT |
Alternate output |
67 |
RAMP |
Ramp signal |
|
Positioning |
156 |
ZRN |
Origin return |
157 |
PLSV |
Variable pulse output |
|
158 |
DRVI |
Corresponding position control |
|
159 |
DRVA |
Absolute position control |
|
Contact comparison instruction |
224 |
LD= |
Start of operation (S1) = (S2) turn on |
225 |
LD﹥ |
Start of operation (S1) ﹥(S2) turn on |
|
226 |
LD﹤ |
Start of operation (S1) ﹥(S2) turn on |
|
228 |
LD﹤﹥ |
Start of operation (S1) ≠(S2) turn on |
|
229 |
LD﹤= |
Start of operation (S1) ≤(S2) turn on |
|
230 |
LD﹥= |
Start of operation (S1) ≥(S2) turn on |
|
232 |
AND = |
Series connection (S1) = (S2) conduction |
|
233 |
AND﹥ |
Series connection (S1) ﹥(S2) conduction |
|
234 |
AND﹤ |
Series connection (S1) ﹥(S2) conduction |
|
Contact comparison instruction |
236 |
AND﹤> |
Series connection (S1) ≠(S2) conduction |
237 |
AND﹤= |
Series connection (S1) ≤(S2) conduction |
|
238 |
AND>= |
Series connection (S1) ≥(S2) conduction |
|
240 |
OR = |
Parallel connection (S1) = (S2) conduction |
|
241 |
OR﹥ |
Parallel connection (S1) ﹥(S2) conduction |
|
242 |
OR﹤ |
Parallel connection (S1) ﹥(S2) conduction |
|
243 |
OR﹤﹥ |
Parallel connection (S1) ≠(S2) conduction |